Fluke BT520
Reduced testing complexity, a simplified workflow and an intuitive user interface provide a new level of ease-of-use in battery testing.
- The ideal test tool for maintenance, troubleshooting and performance testing of individual stationary batteries and battery banks used in critical battery back-up applications
- The intuitive user interface, compact design and rugged construction ensure optimum performance, test results and reliability
- Covers a broad range of battery test functions ranging from DC voltage and resistance tests to full condition testing using automated string function testing and the test probe integrated infra-red temperature measurement system
- Designed for measurements on stationary batteries of all types.
Description
Features
Fluke BT520 Key features: (Designed for measuring batteries in cabinets and hard to reach places)
- All of the above plus
- BTL20 Interactive Test Probe set, with long and short probe extenders and built-in LCD display and speaker for visual and audio feedback
- Large soft carry case
Voltage and Resistance Thresholds
Fluke Battery Analyzers allow you to quickly and easily define upper and lower measurement thresholds or tolerance ranges. During the testing process, measured values are automatically compared to the predefined threshold levels producing a PASS, FAIL or WARN indication after each measurement. A maximum of 10 sets of thresholds can be stored and threshold indications are determined based on the following criterion:
Voltage | Resistance | |||
>Voltage Lower | <Voltage Lower | <Reference | >Reference and < Reference x (1+Warning %) |
>Reference x (1+Fail) |
Pass | Fail | Pass | Warning | Fail |
Fluke Battery Management Software
Fluke Battery Management Software Easily allows you to quickly and easily import data from the battery analyzer to a PC. The measurement data and battery profile information is stored and archived with the Management Software and can be used compare results, switch results between conductance and resistance readings and perform trend analysis. All measurement data, battery profile and analysis information can be used to easily generate reports.
- Quick view saved readings
- Profile management
- Histogram of a battery string with end user defined threshold
- Historical trend data of batteries
- Multiple rounds of discharge voltage
- Quick Report Generation
- Upgrade Fluke Battery Analyzer firmware
- Switch measurement results between conductance and resistance readings
Histogram of a battery string with user defined threshold
Historical trend data of batteries
Multiple rounds of discharge voltage
Specs
Functions | Range | Resolution | Accuracy | BT510 | BT520 | BT521 | |
Battery Resistance / Strap Resistance1 | 3 mΩ | 0.001 mΩ | 1% + 8 | ● | ● | ● | |
30 mΩ | 0.01 mΩ | 0.8% + 6 | ● | ● | ● | ||
300 mΩ | 0.1 mΩ | 0.8% + 6 | ● | ● | ● | ||
3000 mΩ | 1 mΩ | 0.8% + 6 | ● | ● | ● | ||
VDC | 6 V | 0.001 V | 0.09% + 5 | ● | ● | ● | |
60 V | 0.01 V | 0.09% + 5 | ● | ● | ● | ||
600 V | 0.1 V | 0.09% + 5 | ● | ● | ● | ||
1000 V | 1 V | 0.09% + 5 | ● | ||||
VAC (45 Hz to 500 Hz with 800 Hz filter) | 600 V | 0.1 V | 2% + 10 | ● | ● | ● | |
Frequency (displayed with VAC and AAC)2 | 500 Hz | 0.1 Hz | 0.5% + 8 | ● | ● | ● | |
AC voltage ripple (20 KHz Max) | 600 mV | 0.1 mV | 3% + 20 | ● | ● | ● | |
6000 mV | 1 mV | 3% + 10 | ● | ● | ● | ||
ADC/AAC (with accessory Fluke i410) | 400 A | 1 A | 3.5% + 2 | ● | |||
Temperature | 0°C to 60°C | 1°C | 2°C (4°F) | ● | |||
Meter mode | 999 records for each measurement position with time stamp | ||||||
Sequence mode | Up to 100 profiles and 100 profile templates (Each profile stores up to 450 batteries) with time stamp | ||||||
1. The measurement is based on AC injection method. The injected source signal is < 100 mA, 1 kHz. 2. Trigger level VAC: 10 mV, AAC: 10 A |
|||||||
Measurement Modes | BT510 | BT520 | BT521 | ||||
Resistance (mΩ) | ● | ● | ● | ||||
Battery voltage | ● | ● | ● | ||||
Voltage DC | ● | ● | ● | ||||
Voltage AC and frequency (Hz) | ● | ● | ● | ||||
Ripple volt | ● | ● | ● | ||||
Temperature of negative battery post | ● | ||||||
DC and AC current (and frequency) | ● | ||||||
DMM mode | ● | ● | ● | ||||
Sequence mode | ● | ● | |||||
Discharge measurement mode | ● | ● | ● | ||||
Automatic measurement save | ● | ● | ● | ||||
Wireless commumcation | ● | ||||||
Memory view | ● | ● | ● | ||||
General Specifications | |||||||
Size (H x W x D) | 22 x 10.3 x 5.8 cm (9 x 4 x 2 in) | ||||||
Weight | 850 g (1.9 lb) | ||||||
Screen dimensions | 7.7 x 5.6 cm (3 x 2.2 in) | ||||||
Interface | USB mini | ||||||
Warranty | 3 years | ||||||
Environment Specifications | |||||||
Operating temperature | 0°C to 40°C | ||||||
Storage temperature | -20°C to 50°C | ||||||
Lithium-ion battery charging temperature | 0°C to 40°C | ||||||
Operating humidity | Non-condensing (10°C) | ||||||
≤ 80% RH (at 10°C to 30°C) | |||||||
≤ 75% RH (at 30°C to 40°C) | |||||||
Operating altitude | Sea level to 2000 meters | ||||||
Storage altitude | Sea level to 12,000 meters | ||||||
IP rating | IP40 | ||||||
Radio | FCC Class A | ||||||
Vibration requirements | MIL-PRF-28800F: Class 2 | ||||||
Drop test requirements | 1 meter | ||||||
Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C | ||||||
Safety compliance | 600 V CAT III | ||||||
EMC | IEC 61326 | ||||||
ROHS | China, Europe | ||||||
Protection class 2 | Pollution Degree II | ||||||
Battery compliance | UN38.3 | ||||||
UL2054 | |||||||
IEC62133 | |||||||
2 G per IEC68-2-26, 25 G, and 29 |